Skip to main content

Current knowledge about stackable guides: a scoping review

Abstract

Purpose

The rise of stereolithographic surgical guides and digital workflow, combined with a better knowledge of materials and loading principle, has enabled the placement of the temporary prosthesis at the time of implant placement. This scoping review aimed to assess the current knowledge available on stackable guides.

Methods

The review focused on fully edentulous or requiring total edentulism patients. The procedure studied was the use of stackable guides for edentulous patients in order to place immediate temporary prostheses. The clinical endpoint was immediate placement of the provisional prosthesis after surgery combined with a prior bone reduction using a stackable guide.

Results

12 case reports or case series articles met inclusion criteria, which did not allow an analysis by a systematic review. The included studies were case reports or case series. Most of the articles showed a base stabilized by 3 or 4 bone-pins, anchored in buccal or lingual part. Regarding the accuracy of bone reduction (ranged from 0.0248 mm to 1.98 mm) and implant placement when compared to planned, only 4 articles reported quantitative data. 11 articles showed an immediate loading with the transitional prosthesis after implant placement.

Conclusions

There are as yet no prospective or comparative studies on the efficiency of this technique. In a reliable way, stackable guides seem to be able to guide the practitioner from the flap elevation to the placement of the temporary screw-retained implant supported prosthesis. Given the lack of studies in this specific field of guided surgery, further studies are needed to confirm the clinical relevance of this technique.

Graphical Abstract

Background

Implant-supported screw-retained prosthesis is the gold-standard for fixed restoration in completely edentulous patient [1]. Over the past decade, digital workflow has entered the field of surgical and prosthetic implantology. Technological developments (Cone Beam Computed Tomography (CBCT), software, 3D printers, etc.) have made it possible to anticipate the production and delivery of the immediate implant-supported prosthesis. According to the literature, the rise of stereolithographic surgical guide, digital planning, and Computer-Aided Design/Computer-Aided Manufacturing, combined with improved knowledge of materials and the principle of immediate loading has led to a major advance: the delivery of a provisional prosthesis at the time of implant placement [2].

Despite an increased accuracy in implant placement compared with a free-hand surgery [3], guided surgeries could achieve surgical predictability with an average overall implant deviation of 4° from planning [2, 4]. Sometimes, this lack of precision did not allow the immediate placement of the provisional prosthesis when fabricated prior to the placement of implants. In these situations, this implied a very long session to make impressions and record the occlusion relationship following the surgery [5,6,7].

Most of the time, in completely edentulous patients, due to an irregular post-extraction bone anatomy, guided bone reduction may be essential to establish a suitable ridge for implant placement and to fit a bone-supported drill guide [8,9,10,11]. In these specific clinical cases, conventional stereolithographic surgical guides, which are printed solely to guide drilling, cannot be manufactured to anticipate the new anatomical situation. (Fig. 1) Stackable guides are a recent evolution of stereolithographic guides whose main objectives are to achieve both bone reduction, if necessary, and placement of implants planned. The previously fabricated temporary screw-retained prosthesis can then be fitted immediately (for technical note, see Debortoli et al.) [12]. When using stackable guides, placing the bone anchored base is the first stage of a fully guided implant surgery. Different removable guides are connected with the base during the surgery to successively perform the bone reduction, osteotomies, and the placement of implants. (Figures 2, 3, 4, 5, 6, 7, 8, 9 and 10) Thus, the prosthetically-guided implant planning is followed at every stage. This type of surgical guide seems to be promising to facilitate manufacturing and the placement of a temporary prosthesis at the time of surgery, which was more difficult with conventional stereolithographic guides. In fact, the base of these guides is also used to maintain precise positioning of the provisional prosthesis while the temporary abutments are captured in the provisional prosthesis using acrylic resin.

Fig. 1
figure 2

Conventional stereolithographic surgical guide (pilot drill guide)

Fig. 2
figure 3

Stackable guide: base

Fig. 3
figure 4

Stackable guide: base + 1rst stage (base positioning using remaining teeth)

Fig. 4
figure 5

Stackable guide: base + 2nd stage for fully guided implant placement

Fig. 5
figure 6

Stackable guide: base + 1rst stage (base positioning) in a clinical situation

Fig. 6
figure 7

Anchored base before multiple extractions

Fig. 7
figure 8

Anchored base after multiple extractions

Fig. 8
figure 9

Stackable guide: base + 2nd stage for fully guided implant placement

Fig. 9
figure 10

Fully guided osteotomies

Fig. 10
figure 11

Implants placed at the end of fully guided surgery

The aim of this review is to assess the current knowledge available on stackable guides and actual contributions and limits of this device in both surgical and prosthetic procedures.

Materials and methods

In this scoping review, the target population is completely edentulous patients or patients requiring total edentulism. All types of studies with unlimited publication period have been collected between March and May 2023 on Medline database. The procedure studied was the use of stackable guides for edentulous patients in order to place immediate temporary prostheses. The clinical endpoint was immediate placement of the provisional prosthesis after surgery combined with a prior bone reduction using a stackable guide. Other aspects of computer assisted surgery like computer guided surgery without immediate provisional placement and dynamic navigation were not studied.

Studies of partially edentulous patients whose teeth were retained or articles on freehand or non-stackable-guided surgery were not included. Animal or in vitro studies, studies published in a language other than English, and full texts not accessible via inter-university credits were excluded. Publications meeting the selection criteria were included by two independent readers according to the PRISMA methodology (PRISMA Extension for Scoping Reviews) [13].

The search started with the use of MeSH terms to obtain a search equation including the target population, the type of targeted intervention and the placement of a temporary prosthesis: “edentulous jaw AND computer aided surgery AND dental implant AND temporary prosthesis”. With this search equation, the articles obtained were too irrelevant, mostly focusing on conventional stereolithographic guides. Thus, free keywords were used in PubMed database to achieve this review: “stackable template OR stackable implant placement guide OR stackable surgical template”. This search was supplemented by a manual search in the PubMed database. General and clinical information were collected within the limitations of reported data.

Results

We collected 12 articles that met inclusion criteria [14,15,16,17,18,19,20,21,22,23,24,25]. (Table 1)

Table 1 Summary of the inclusion and exclusion criteria

The included studies were case reports (25 patients; 27 arches restored, 173 implants), corresponding to low level of evidence studies. (Tables 2 and 3)

Table 2 Summary of patients treated in included studies

- Stackable guide:

Depending on clinical cases, the guide support tissue could be different: mucosal-supported guides, bone-anchored guide, dental-supported guide and mixed-supported guide (dental and mucosal or dental and bone).

Of the 12 articles selected, regarding material used to manufacture surgical guides, only two articles reported metal alloy surgical guides, manufactured by selective laser melting [18, 25]. In the other articles, 3D printed acrylic resin was used to manufacture all the stages of stackable guides, from basis to temporary prosthesis. (Table 3)

Table 3 Characteristics of the stackable guides used in selected studies

Regarding the stabilization of the guide, most of the articles showed guides with a base stabilized by 3 or 4 bone-pins, anchored in buccal or lingual part [14, 15, 17,18,19,20,21,22, 24, 25]. Only one article showed an unanchored mucosa-supported guide [23].

The number of stacked parts varied: 2 articles reported 2-part guides, 7 articles reported 3-part guides and 3 articles reported 4-part guides. When 4 stacked parts were present, the first part is tooth-supported to perform an accurate positioning of a bone-pin anchored base. This first part was then removed, and the bone resection is performed using the second part. The third part allowed full-guided osteotomies and implant placements. The temporary guided prosthesis was positioned using the last part. In case of edentulous patients, 3 or 4 stacked parts could constitute the guide. When there were two parts, a base was present on which a drilling guide or a guide for the sinus approach is positioned.

Different devices were described to connect the different parts: 5 articles described screws or pins [14, 23,24,25,26], 2 articles described ball attachments [15, 20], 2 articles described magnetic attachments [16, 19], 4 articles described notches [17, 18, 21, 22].

Regarding placement or stabilization, no problem was reported.

- Placement of the provisional prosthesis and stackable guide accuracy:

11 articles [14, 15, 17,18,19,20,21,22,23,24,25] reported immediate loading procedures. Regarding the accuracy of bone reduction and implant placement in relation to planning, only 4 articles reported quantitative data allowed by a superimposition of CBCTs before (surgical planning) and after the placement of implants [11, 19, 22, 23]. The difference was analyzed using a different calculation software and the data was expressed in millimeter or degrees depending on the value indicated. According to the authors, the accuracy of the actual bone reduction ranged from 0.0248 mm to 1.98 mm when compared with the reduction initially planned; one author reports a bone plane inclination of 6.03° [22]. Regarding implant placement, accuracy ranged from 0.44 mm to 1.43 mm at the implant apex, from 0.887 mm to 1.90 mm at the implant neck, and from 2.4° to 4.14° in overall implant deviation depending on the author [11, 16, 19].

Discussion

The use of stackable guides is a developing practice. Given the lack of studies in this specific field of guided surgery, the authors concluded that a systematic review was irrelevant. The results should be noted with caution, without the possibility of recommendations or conclusions for clinical practice.

This scoping review has enabled to identify several important points, both positive and negative.

- Placement of the surgical guide:

When there are still teeth on the jaw, the authors seemed to favour anchoring the base using the remaining teeth [11, 18, 26], which is also reported in the literature to improve the accuracy of guide positioning [26,27,28]. When the teeth are too mobile (e.g. due to periodontal disease), a splint could be made before the CBCT to prevent any movement that would destabilize the positioning of the base [25]. An optical impression is recommended to avoid tooth movement, which would result in a distorted planning [29].

In addition, in cases of simultaneous extraction/implant placement, the dislocation movement of teeth during extraction may deform the bony tables which may complicate the placement of the guide on these modified supporting tissues. Even without bone deformation, stabilizing the guide on extraction sockets could be challenging [20]. The stackable guide provides a secure base with bone-pins and accurate placement with the dental support used prior to extractions.

In edentulous patients, attention must be paid to the compression zone between the supporting tissues and the surgical guide so as not to destabilize the latter. When the base of the stackable guide is supported by soft tissues, oedema caused by local anesthesia may lead to positioning errors. In these clinical situations, it is important to infiltrate the anesthetic solution away from the support area [14].

In cases of limited mouth opening, stacking of the guide stages may be very complicated or even impossible and the use of these guides is therefore contraindicated [24].

Although selected studies were of low level of evidence, few of them have reported data between planed and final bone reduction or implant placement [11, 16, 19, 22]. Obviously, these data can only give a trend that needs to be supported by further studies, but they seem to show small discrepancies between planning and realization.

- Stacking of the guide stages:

According to Costa et al., magnetic attachments allow for stable and reproducible stacking of guide bases [16]. The characteristics of attachment devices were not well developed in the selected studies.

- Possible planning in case of bone reduction of the ridge:

In completely edentulous patients, the drill guide will be bone-supported; if bone resection is required, a full flap is lifted so mucosal support is not possible. The surgeon will not be able to achieve an accurate free-hand bone reduction to fit the drill guide. After ridge resection, anatomical landmarks are modified, making it difficult to position the guide later [14].

The interest in guiding bone reduction is major as it would allow the use of drill guides even in patients requiring bone resection. Once the intraosseous pins of the base are placed, the reduction can be performed up to the limit of the guide, which represents bone margins planned on software before the surgery. Then a drill guide is “nested” on the base to allow a fully guided surgery from ridge reduction to implant placement. In this way, the resection is guided, and the new bone level is true to plan [11, 14, 16, 18, 21,22,23,24].

- Placement of the provisional prosthesis:

The immediate loading of the screw-retained temporary prosthesis avoids repetitive screwing/unscrewing of the implant superstructures. The provisional prosthesis is directly placed until complete osseointegration of the implants. D’Haese et al. have shown that mobilizing the implants too early during screwing/unscrewing can lead to deviation of the implant axes from the planning [30].

In addition, the prosthesis is manufactured before surgery, thus avoiding postoperative impressions which are more complex to manage at the end of surgery. When the provisional prosthesis is obtained by transforming of the temporary removable complete denture, the risk of fracture of the prosthesis is high [31]. Moreover, of the various milled materials available, polymethyl methacrylate can be used to manufacture prostheses with improved mechanical properties [29, 32].

During the digital design of the temporary prosthesis, the implant positions lead to the choice of abutment height and angulation. This step ensures the necessary passivity of the prosthesis to avoid any iatrogenic stresses on the implants during the osseointegration phase [20]. Planning is a time-consuming step, but it saves time during surgery and limits prosthetic sessions. Indeed, the temporary restoration can be placed directly after implant placement. This avoids leaving the patient without a prosthesis for 24–48 h as well as an often poorly tolerated impression and bite registration session at the end of the surgery [4, 16, 23, 28].

- Decrease in patient comorbidities:

These static guides eliminate the need for full flap surgery [33]. Indeed, it is no longer necessary to see the underlying bone structure because the guide has been designed based on a careful and accurate CBCT analysis. A flapless surgery can be performed, operating time is significantly shortened, and postoperative comorbidities decrease (bleeding, pain, oedema, hematoma) [4, 23].

Patient and surgeon comfort is improved, and the immediate loading of the implants also avoids a difficult impression session [20].

- Digital workflow:

Digital workflow is an interesting procedure that could help in treatment planning and virtual prosthetic project. Indeed, planning is done virtually on dedicated software with superimposition of DICOM files and STL files (initial situation from intraoral scanning and virtual prosthetic project). Then printing surgical templates made it possible to transfer this prosthetically guided project from the computer to the patient [34]. Several authors have reported no differences in the clinical accuracy of implant placement between additive and subtractive manufactured guides [35, 36]. In addition, acrylic resin is a suitable material for the manufacture of surgical guides, with the benefits of ease fabrication, reduced cost and less time wasted by technicians [36, 37].

There also are many advantages to this digital workflow: fewer clinical sessions are required, the provisional prosthesis fits better, and the placement of implants is more accurate [16, 38].

Limits.

- Persistent risk of error:

Despite the promising concept of stackable guides, errors can accumulate throughout treatment steps (CBCT acquisition, wax up, distortion of the planned manufacture of the guide, calibration of the 3D printer, surgical phase, anchoring the guide during surgery, stacking the different parts). The practitioner’s experience is essential in order to remain focus on the progress of each step during the surgery and be able to fix any problem or mistakes [14, 15, 19, 21].

Main limits are in the need to acquire knowledge and experience in this field; as most of new techniques, it requires a learning curve for both surgeons and dental technicians, and the need for a specific software (initial investment required).

Obviously, limits in the use of conventional stereolithographic guide are available for stackable guide (mouth opening, remaining errors in positioning the base…).

The absence of postoperative control radiography in most studies (6/12) made it impossible to objectively assess the real effectiveness of the technique presented, or the correct temporary prosthesis positioning with regard to biological or prosthetic requirements. The results should therefore be interpreted with caution.

- Financial cost:

Manufacturing the guide adds a cost to the treatment, particularly when using magnetic attachments [14, 16].

Clinical relevance:

There is no study with good levels of evidence to evaluate and measure the benefit of stackable surgery guide. However, this surgical technique appears promising in order to improve surgical precision. It differs from the use of conventional stereolithographic guides which are already used daily by several practitioners. Deep analysis and complete planning of each clinical case are time-consuming but essential steps to achieve an optimal temporary the comfort for both surgeon and patient.

In return, the comfort for both surgeon and patient is clearly increased and the surgery becomes more reproducible. (Table 4)

Table 4 Advantages / Disadvantages of stackable guides

Conclusions

There are as yet no prospective or comparative studies on the efficiency of stackable stereolithographic surgical guides, and the data found in the literature are not standardized. Only case series are reported, which makes it impossible to justify a possible impact on clinical practice.

The management of bone reduction prior to implant placement or immediate loading of a temporary prosthesis could be facilitated by using a stackable guide, which appears to be able to guide the practitioner from surgery to immediate loading of the provisional screw-retained implant-supported prosthesis.

Further studies are therefore needed to confirm the improved accuracy of implant placement and prosthetic success in immediate loading. Given the growth of dynamic guided surgeries, in-depth studies are also needed to assess the benefits of promoting this type of surgical guide.

Data availability

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

References

  1. Del Fabbro M, Pozzi A, Romeo D, de Araújo Nobre M, Agliardi E. Outcomes of fixed full-arch rehabilitations supported by Tilted and axially placed implants: a systematic review and Meta-analysis. Int J Oral Maxillofac Implants. 2022;37:1003–25.

    Article  PubMed  Google Scholar 

  2. Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: a systematic review and meta-analysis. Clin Oral Implants Res. 2018;29(Suppl 16):416–35.

    Article  PubMed  Google Scholar 

  3. Varga E Jr, Antal M, Major L, Kiscsatári R, Braunitzer G, Piffkó J. Guidance means accuracy: a randomized clinical trial on freehand versus guided dental implantation. Clin Oral Implants Res. 2020;31:417–30.

    Article  PubMed  Google Scholar 

  4. Gargallo-Albiol J, Barootchi S, Salomó-Coll O, Wang HL. Advantages and disadvantages of implant navigation surgery. A systematic review. Ann Anat. 2019;225:1–10.

    Article  PubMed  Google Scholar 

  5. Maille G, Loyer E. Immediate occlusal loading of implants: a rapid chairside procedure for making an interim fixed prosthesis. J Prosthet Dent. 2019;121:358–60.

    Article  PubMed  Google Scholar 

  6. D’haese J, Van De Velde T, Komiyama A, Hultin M, De Bruyn H. Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature. Clin Implant Dent Relat Res. 2012;14:321–35.

    Article  PubMed  Google Scholar 

  7. Abduo J, Lau D. Seating accuracy of implant immediate provisional prostheses fabricated by digital workflow prior to implant placement by fully guided static computer-assisted implant surgery: an in vitro study. Clin Oral Implants Res. 2021;32:608–18.

    Article  PubMed  Google Scholar 

  8. Ganz SD. Techniques for the use of CT imaging for the fabrication of surgical guides. Atlas Oral Maxillofac Surg Clin North Am. 2006;14:75–97.

    Article  PubMed  Google Scholar 

  9. Alzoubi F, Massoomi N, Nattestad A. Bone reduction to facilitate Immediate Implant Placement and Loading using CAD/CAM Surgical guides for patients with terminal dentition. J Oral Implantol. 2016;42:406–10.

    Article  PubMed  Google Scholar 

  10. Mijiritsky E, Ben Zaken H, Shacham M, Cinar IC, Tore C, Nagy K, et al. Variety of Surgical guides and protocols for Bone Reduction Prior to Implant Placement: a narrative review. Int J Environ Res Public Health. 2021;18:2341.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Faeghi Nejad M, Proussaefs P, Lozada J. Combining guided alveolar ridge reduction and guided implant placement for all-on-4 surgery: a clinical report. J Prosthet Dent. 2016;115:662–67.

    Article  PubMed  Google Scholar 

  12. Debortoli C, Afota F, Latreche S, Zammillo F, Boujenah O, Savoldelli C. Stackable guide in implantology: a technical note. J Stomatol Oral Maxillofac Surg. 2023. https://doi.org/10.1016/j.jormas.2023.101459.

    Article  PubMed  Google Scholar 

  13. Tricco AC, Lillie E, Zarin W, O’Brien KK, Colquhoun H, Levac D, et al. PRISMA Extension for scoping reviews (PRISMA-ScR): Checklist and Explanation. Ann Intern Med. 2018;169:467–73.

    Article  PubMed  Google Scholar 

  14. Baruffaldi A, Baruffaldi A, Baruffaldi M, Maiorana C, Poli PP. A suggested protocol to increase the accuracy of prosthetic phases in case of full-arch model-free fully guided computer-aided implant placement and immediate loading. Oral Maxillofac Surg. 2020;24:343–51.

    Article  CAS  PubMed  Google Scholar 

  15. Beretta M, Poli PP, Tansella S, Maiorana C. Virtually guided alveolar ridge reduction combined with computer-aided implant placement for a bimaxillary implant-supported rehabilitation: a clinical report. J Prosthet Dent. 2018;120:168–72.

    Article  PubMed  Google Scholar 

  16. Costa AJM, Teixeira Neto AD, Burgoa S, Gutierrez V, Cortes ARG. Fully Digital Workflow with magnetically connected guides for full-arch Implant Rehabilitation following guided Alveolar Ridge reduction. J Prosthodont. 2020;29:272–6.

    Article  PubMed  Google Scholar 

  17. Creagh J, Bohner L, Sesma N, Coachman C. Integrating a facially driven Treatment Planning to the Digital Workflow for Rehabilitation of Edentulous arches: a Case Report. J Contemp Dent Pract. 2020;21:1393–7.

    Article  PubMed  Google Scholar 

  18. Fu X, Yang J, Luo J, Zhang Y. Three-dimensional facial esthetics-driven computer-assisted osteotomy and implant placement for immediate restoration of a failing dentition with a protruded maxilla. J Prosthet Dent. 2022;127:392–7.

    Article  PubMed  Google Scholar 

  19. García-Sala Bonmati F, Pérez-Barquero JA, Ilzarbe Ripoll LM, Labaig Rueda C, Fernandez-Estevan L, Revilla-León M. An additively manufactured, magnetically retained, and stackable implant surgical guide: a dental technique. J Prosthet Dent. 2023;130:444–52.

    Article  PubMed  Google Scholar 

  20. Granata S, Sforza NM, Giberti L, Stellini E, Di Fiore A. Computer-guided implant surgery for immediate implanting and loading: the STIL technique. J Prosthet Dent. 2021;126:155–63.

    Article  PubMed  Google Scholar 

  21. Lanis A, Tahmaseb A. Computer-assisted bone reduction and static computer-guided implant surgery in a fully edentulous patient: a technique report. Int J Comput Dent. 2021;24:165–79.

    PubMed  Google Scholar 

  22. Lu JY, Yu JY, Xie CY, Gao J, Yu HY. Immediate precision of the digital osteotomy template in the digital stackable template: a clinical study. Hua Xi Kou Qiang Yi Xue Za Zhi. 2021;39:732–8.

    PubMed  Google Scholar 

  23. Papaspyridakos P, De Souza A, Bathija A, Kang K, Chochlidakis K. Complete Digital Workflow for Mandibular Full-Arch Implant Rehabilitation in 3 appointments. J Prosthodont. 2021;30:548–52.

    Article  PubMed  Google Scholar 

  24. Salama MA, Pozzi A, Clark WA, Tadros M, Hansson L, Adar P. The Scalloped Guide: a proof-of-Concept technique for a digitally streamlined, Pink-Free full-arch Implant Protocol. Int J Periodontics Restor Dent. 2018;38:791–8.

    Article  Google Scholar 

  25. Yang JW, Liu Q, Yue ZG, Hou JX, Afrashtehfar KI. Digital Workflow for full-Arch Immediate Implant Placement using a Stackable Surgical Guide fabricated using SLM technology. J Prosthodont. 2021;30:645–50.

    Article  PubMed  Google Scholar 

  26. Geng W, Liu C, Su Y, Li J, Zhou Y. Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement. Int J Clin Exp Med. 2015;8:8442–9.

    PubMed  PubMed Central  Google Scholar 

  27. Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2014;29 Suppl:25–42.

    Article  PubMed  Google Scholar 

  28. Sigcho López DA, García I, Da Silva Salomao G. Cruz Laganá D. potential deviation factors affecting Stereolithographic Surgical guides: a systematic review. Implant Dent. 2019;28:68–73.

    Article  PubMed  Google Scholar 

  29. Orentlicher G, Horowitz A, Kobren L. Computer-Guided Dental Implant Treatment of Complete Arch Restoration of Edentulous and Terminal Dentition patients. Oral Maxillofac Surg Clin North Am. 2019;31:399–426.

    Article  PubMed  Google Scholar 

  30. D’Haese J, Van De Velde T, Elaut L, De Bruyn H. A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae. Clin Implant Dent Relat Res. 2012;14:293–303.

    Article  PubMed  Google Scholar 

  31. Penarrocha-Diago M, Penarrocha-Diago M, Zaragozí-Alonso R, Soto-Penaloza D, On Behalf Of The Ticare Consensus M. Consensus statements and clinical recommendations on treatment indications, surgical procedures, prosthetic protocols and complications following All-On-4 standard treatment. 9th Mozo-Grau Ticare Conference in Quintanilla, Spain. J Clin Exp Dent. 2017;9:e712-e715.

  32. Bergamo ETP, Campos TMB, Piza MMT, Gutierrez E, Lopes ACO, Witek L, et al. Temporary materials used in prosthodontics: the effect of composition, fabrication mode, and aging on mechanical properties. J Mech Behav Biomed Mater. 2022. https://doi.org/10.1016/j.jmbbm.2022.105333.

    Article  PubMed  Google Scholar 

  33. Deeb JG, Bencharit S, Loschiavo CA, Yeung M, Laskin D, Deeb GR. Do Implant Surgical guides allow an adequate zone of Keratinized tissue for flapless surgery? J Oral Maxillofac Surg. 2018;76:2540–50.

    Article  PubMed  Google Scholar 

  34. Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent. 2013;109:361–6.

    Article  PubMed  Google Scholar 

  35. Keßler A, Dosch M, Reymus M, Folwaczny M. Influence of 3D-printing method, resin material, and sterilization on the accuracy of virtually designed surgical implant guides. J Prosthet Dent. 2022;128:196–204.

    Article  PubMed  Google Scholar 

  36. Shi Y, Wang J, Ma C, Shen J, Dong X, Lin D. A systematic review of the accuracy of digital surgical guides for dental implantation. Int J Implant Dent. 2023;9:38. https://doi.org/10.1186/s40729-023-00507-w.

    Article  PubMed  PubMed Central  Google Scholar 

  37. Henprasert P, Dawson DV, El-Kerdani T, Song X, Couso-Queiruga E, Holloway JA. Comparison of the Accuracy of Implant position using Surgical guides fabricated by additive and subtractive techniques. J Prosthodont. 2020;29:534–41.

    Article  PubMed  Google Scholar 

  38. Siqueira R, Chen Z, Galli M, Saleh I, Wang HL, Chan HL. Does a fully digital workflow improve the accuracy of computer-assisted implant surgery in partially edentulous patients? A systematic review of clinical trials. Clin Implant Dent Relat Res. 2020;22:660–71.

    Article  PubMed  Google Scholar 

Download references

Funding

There is no funding related to this article.

Author information

Authors and Affiliations

Authors

Contributions

LR: conception, design, interpretation of result, drafting and editing the manuscript. CMa: literature screening, drafting. CMe: literature screening, interpretation of result. FS: conception, design, literature screening, interpretation of result, drafting and editing the manuscript.

Corresponding author

Correspondence to Frédéric Silvestri.

Ethics declarations

Ethics approval and consent

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary Material 1

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lan, R., Marteau, C., Mense, C. et al. Current knowledge about stackable guides: a scoping review. Int J Implant Dent 10, 28 (2024). https://doi.org/10.1186/s40729-024-00547-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40729-024-00547-w

Keywords