Skip to main content

Table 9 Implant failure case in the mandible

From: The All-on-four concept for fixed full-arch rehabilitation of the edentulous maxilla and mandible: a longitudinal study in Japanese patients with 3–17-year follow-up and analysis of risk factors for survival rate

Case

Age

Sex

Smoking

Systemic disease

Surgical procedure (number of implants)

Type of implant

Diameter (mm)

Length (mm)

Primary stability (N cm)

Direction

Time to implant failure (month)

1

63

M

 + 

Stomach cancer

All-on-four (4)

Nobel speedy groovy

4.0

18

45

Tilted

74

2

58

M

 + 

All-on-four (4)

Nobel speedy groovy

4.0

15

35

Tilted

1

3

67

F

All-on-four + 2 (6)

Nobel speedy groovy

4.0

18

50 ≤ 

Tilted

140

      

Nobel speedy groovy

4.0

7

40

Straight

140

4

55

M

 + 

Hepatic dysfunction

All-on-four (4)

Nobel speedy groovy

4.0

15

50 ≤ 

Straight

7

5

38

M

 + 

DM

All-on-four (4)

Nobel speedy groovy

4.0

15

50 ≤ 

Tilted

9

6

47

M

 + 

All-on-four (4)

Nobel speedy groovy

4.0

18

50 ≤ 

Tilted

28