Skip to main content

Table 1 Volume measurements

From: A novel approach to determining augmented bone volume in intraoral bone block augmentation using an intraoral scanner: an in vitro study

 

Time-point

Semi-automatic (N = 19) [cm3]

Manual (N = 20) [cm3]

Total (N = 39) [cm3]

Mean difference [90% Confidence Interval]

p values (TOST, NHST)

Block augmentation

T0

0.35 ± 0.081

0.36 ± 0.091

0.35 ± 0.085

− 0.008 [− 0.054, 0.038]

 < 0.001*, 0.773

T1

0.34 ± 0.091

0.35 ± 0.085

0.35 ± 0.087

− 0.015 [− 0.062, 0.033]

 < 0.001*, 0.609

Split block augmentation

T0

0.73 ± 0.15

0.78 ± 0.14

0.75 ± 0.14

− 0.05 [− 0.127, 0.027]

0.017*, 0.280

T1

0.75 ± 0.15

0.78 ± 0.15

0.76 ± 0.15

− 0.034 [− 0.115, 0.046]

0.010*, 0.475

Shell augmentation

T0

0.80 ± 0.19

0.86 ± 0.17

0.83 ± 0.18

− 0.066 [− 0.161, 0.029]

0.073, 0.248

T1

0.80 ± 0.18

0.84 ± 016

0.82 ± 0.17

− 0.042 [− 0.134, 0.051]

0.028*, 0.452

  1. The measured values of augmented volume for the different augmentation techniques, time points and measurement techniques. TOST: Test of One-Sided Significance, NHST: Null Hypothesis Significance Testing
  2. *Statistically significant with significance level alpha < 0.05