Skip to main content

Table 4 Review of PSAA data from other studies

From: Anatomical variations and accessory structures in the maxilla in relation to implantological procedures: an observational retrospective study of 212 cases using cone-bean computed tomography

Study

Sample

No. maxillary sinuses

% detection

Most frequent type

Ø (mm)

Ridge (mm)

Present study

212 CBCT

424

99.10%

I

1.1

16.2

Anamali et al. [19]

254 CBCT

508

90.90%

No data

No data

No data

Elian et al. [32]

50 CT

100

52.90%

II

No data

16.4

Güncü et al. [22]

121 CBCT

242

64.50%

II

1.3

18

Ilgüy et al. [20]

135 CBCT

270

89.30%

II

0.94

16.88

Kang et al. [33]

150 CT

150

64.3

 

1.18

17.03

Khojastepour et al. [23]

150 CBCT

211

70.30%

I

0.98–1.52

15.72–17.25

Lozano-Carrascal et al. [25]

284 CBCT

568

48.60%

I

 < 1 mm

13.15

Mardinger et al. [21]

104 CT

208

55%

I

 < 1 mm

19.59

Rosano et al. [26]

15 CT, cadavers

30

100%

II

 < 1 mm

11.25

ÅžimÅŸek Kaya et al. [24]

114 CBCT

228

87.70%

II

1–2 mm

15.6

Varela-Centelles et al. [30]

120 CBCT

240

100%

II

1.3

No data