Skip to main content

Table 3 Comparison of CT mean gray values (average of the axial, coronal, and sagittal ROIs) as a function of arch, dental region, insertion torque, and bone types as classified by CT visual assessment and by intra-surgical tactile evaluation

From: Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants

Variable

Meana

Std error

95% confidence interval

P value (F; DF)

Arch

   

< 0.001

 Maxilla

1358A

38.1

[1281–1436]

(27.974; 1)

 Mandible

1636B

36.1

[1563–1709]

 

Dental region

   

0.014

 Premolar

1661A

68.7

[1521–1800]

(6.641; 1)

 Molar

1460B

36.7

[1386–1535]

 

Insertion torque

   

0.002

 < 15 N cm

1375A

49.5

[1274–1476]

(7.595; 2)

 15 to 35 N cm

1510AB

49.5

[1409–1611]

 

 > 35 N cm

1667B

56.4

[1552–1782]

 

Tactile evaluation

   

0.001

 Bone type 2

1650A

60.0

[1528–1772]

(8.703; 2)

 Bone type 3

1537A

43.8

[1447–1626]

 

 Bone type 4

1341B

49.0

[1242–1441]

 

CT visual evaluation

   

0.015

 Bone type 2

1742A

83.4

[1571–1912]

(4.828; 2)

 Bone type 3

1495B

46.6

[1399–1590]

 

 Bone type 4

1434B

56.2

[1318–1549]

 
  1. aMeans followed by distinct letters are statistically different at a significance level of 0.05 (one-way ANOVA and pairwise comparisons by Tukey HSD)