Table 1 Material properties

From: Significance of mandibular molar replacement with a dental implant: a theoretical study with nonlinear finite element analysis

Material

Modulus of elasticity (MPa)

Poisson ratio

References

Cortical bone

140,000

0.3

Kunavisarut et al. [26]

Cancellous bone

7900

0.3

Kunavisarut et al. [26]

Enamel

80,000

0.3

Korioth and Hannan [24]

Dentin

17,600

0.25

Korioth and Hannan [24]

Implant (titan)

117,000

0.32

Kunavisarut et al. [26]

Superstructure (gold alloy)

94,000

0.3

Van Zyl et al. [25], Kitamura et al. [28], Kobayashi et al. [27]

PDL phase1

0.33

0.3

Kim et al. [23], Misch [22], Perfitt et al. [20], Miura et al. [21]

PDL phase 2

16

0.45

Kim et al. [23], Misch [22], Perfitt et al. [20], Miura et al. [21]